Dexterra
Direct SmartRecruiters career site

Electrician Maintenance

Location
Offutt Air Force Base, NE · On-site
Job type
Full-time
Level
Senior
Experience
5+ years
Education
High school diploma or equivalent
Listed
19 days ago

Skills & highlights for this role

  • Electrical troubleshooting and repair of distribution systems, switchgear, transformers, transfer switches, generators, UPS systems, motors, controls, lighting, grounding, and lightning protection
  • Interpretation of blueprints, as-built drawings, and electrical diagrams
  • Load calculations
  • Knowledge of National Electrical Code, NFPA, OSHA, UFC, and Air Force electrical requirements
  • Lockout/tagout and arc-flash safety compliance
  • Electrical hand tools, meters, and testing instruments
  • Documentation in NexGen IT/TRIRIGA or Government-designated systems

Also useful

  • Priority 1 emergency response
  • HEMP-protected area work experience
  • Electrical coordination studies and redline drawing maintenance
  • Generator and UPS load testing

About the role

The Electrician Maintenance performs preventive and corrective maintenance, inspection, testing, troubleshooting, installation, and repair of real property and real property installed electrical systems supporting CMI's customer in Omaha, NE.

Key Job Functions Supports continuous mission readiness by maintaining safe, reliable low- and medium-voltage distribution, emergency power, lighting, grounding, lightning protection, and related electrical infrastructure in accordance with applicable codes, manufacturer requirements, and Government procedures.

Maintain, inspect, test, troubleshoot, repair, and install low- and medium-voltage electrical systems below 4,160 volts, including switchgear, transformers, panelboards, branch circuits, distribution equipment, controllers, circuit breakers, motors, outlets, and manual and automatic transfer switches.

Operate, inspect, test, and maintain emergency generators and associated backup-power equipment; support restoration of backup power within 15 minutes of an outage when assigned to operate emergency generators. Perform quarterly inspections and annual load testing of uninterruptible power supply systems and batteries that support life-safety real property installed equipment.

Repair or replace interior and applicable exterior lighting fixtures, matching existing material, type, color temperature, and lumen output. Maintain, test, and repair grounding, lightning protection, and applicable corrosion-control systems in accordance with current UFC, NFPA, Air Force, and manufacturer requirements.

Perform standard electrical maintenance within and supporting HEMP-protected areas without disturbing the HEMP shield or specialized points-of-entry devices; coordinate required outages or work affecting HEMP interfaces with the Government.

Read and interpret blueprints, as-built drawings, electrical diagrams, layouts, specifications, and manufacturer instructions; perform load calculations and use electrical hand tools, meters, and testing instruments. Document labor, materials, equipment usage, as-found and as-left conditions, cause and remedy, asset information, and completion notes in NexGen IT/TRIRIGA or other Government-designated systems.

Support preventive maintenance schedules, asset inventories, condition assessments, lifecycle planning, calibration records, electrical coordination studies, redline drawings, and required outage and generator reports. Respond to Priority 1 electrical emergencies, initiate on-site mitigation within required response times, and participate in root-cause analysis for qualifying failures.

Coordinate planned outages at least 14 calendar days in advance and immediately report unplanned outages, restoration status, and known causes to designated Government representatives. Comply with lockout/tagout, arc-flash, fall protection, confined-space, PPE, environmental, security, and controlled-area access requirements, and maintain safe, orderly electrical and mechanical work areas.

Qualifications & Requirements

  • High school diploma or equivalent required.
  • Completion of a formal electrical apprenticeship or equivalent combination of technical training and directly related experience required.
  • Minimum 5 years of experience maintaining electrical systems in large commercial, industrial, mission-critical, or comparable facilities.

Must hold and maintain all electrician licenses and certifications required by Nebraska, a state recognized by Nebraska, and applicable local electrical codes. Working knowledge of the National Electrical Code, NFPA requirements, OSHA standards, applicable Unified Facilities Criteria, Air Force electrical requirements, and manufacturer specifications.

  • Demonstrated ability to troubleshoot, maintain, and repair electrical distribution systems, switchgear, transformers, transfer switches, generators, UPS systems, motors, controls, lighting, grounding, and lightning protection systems.
  • Training and demonstrated competency in electrical and arc-flash safety, lockout/tagout, PPE, fall protection, ladders, mobile elevated work platforms, confined spaces, rigging, and other safety topics applicable to assigned work.

Ability to use computerized maintenance management systems and accurately document work orders, asset data, labor, materials, testing results, and corrective actions; NexGen IT/TRIRIGA experience is preferred. Must be able to obtain and maintain required Government credentials, including a Common Access Card when needed for system access, and comply with background investigation requirements.

  • Must possess and maintain at least a Secret security clearance; a Top Secret clearance is required when assigned access to Top Secret or TS/SCI areas.
  • U.S. citizenship is required for clearance eligibility.
  • Must be available to support 24/7 mission-essential operations, emergency response, federal holidays, severe weather events, and Government shutdown periods as assigned.

About the Company

CMI is now a part of the Dexterra Group! CMI Management LLC is headquartered in Alexandria, VA and is a proven provider of efficient business, technology and facilities management solutions designed to help government and commercial clients reduce operational costs, operate at optimum performance and access the information needed for daily and long-term productivity. CMI has been in business for over 30 years and is well established in the federal contracting arena.

Read the original posting

From Dexterra's careers page, first listed on Rolev.ai on October 21, 2026. Rolev.ai is not the employer.

How Rolev.ai helps with this application

Rolev.ai is a job search and application tool for US job seekers. For this Electrician Maintenance role at Dexterra, it shows how your resume fits, tailors your resume to the posting, and prepares the application for you to review.

  • See how you fit

    Openings from employer career sites are ranked against your whole resume—and searchable inside Claude, ChatGPT, and Cursor via Rolev.ai MCP.

  • Tailor without inventing

    Every change to your resume is checked against your original. New experience goes in only with your yes—zero fabricated claims.

  • Draft the full kit

    Tailored and Full Match resumes, role-specific cover letters, and answers to employer screening questions are prepared in seconds.

  • 1-Click Extension Autofill

    The Chrome extension fills the employer's Greenhouse, Workday, Lever, or Ashby form in 1 click. You review it and press Submit.

Common questions

Where is the Electrician Maintenance job at Dexterra located?

This Electrician Maintenance position at Dexterra is located in Offutt Air Force Base, NE (On-site). Always check Dexterra's application page for specific state eligibility or relocation policies.

What qualifications are required for Electrician Maintenance at Dexterra?

For the Electrician Maintenance role, Dexterra highlights 5+ years of relevant experience; a high school diploma or equivalent; experience with Electrical troubleshooting and repair of distribution systems, switchgear, transformers, transfer switches, generators, UPS systems, motors, controls, lighting, grounding, and lightning protection, Interpretation of blueprints, as-built drawings, and electrical diagrams, Load calculations, Knowledge of National Electrical Code, NFPA, OSHA, UFC, and Air Force electrical requirements, Lockout/tagout and arc-flash safety compliance, Electrical hand tools, meters, and testing instruments. Rolev.ai can score your existing resume against these requirements and show any skill gaps before you apply.

How do I apply for the Electrician Maintenance position at Dexterra?

This listing links directly to Dexterra's SmartRecruiters application page. You can apply directly on Dexterra's site, or use Rolev.ai to check your resume fit, generate a zero-hallucination tailored resume and cover letter for this posting, and autofill the SmartRecruiters application form in 1 click with the Rolev.ai Chrome extension. You always review the form and press Submit yourself.