Asgi
Direct BambooHR career site

Fire Alarm Technician

Pay
$85,000 – $95,000 per year
Location
Honolulu, HI
Posted
66 days ago
Free · No account needed

How well does your resume fit this job?

Upload your resume to see your score for this Asgi role, what matches, what's missing, and your best other matches.

Scored on our server and not saved there. The file stays in this browser so you don't have to upload it again after you sign up.

Job Purpose

The Fire Alarm Technician is responsible for the inspection, testing, maintenance, troubleshooting, and repair of fire alarm and detection systems at Joint Base Pearl Harbor-Hickam (JBPHH) and designated outlying military installations throughout Hawaii. The position supports the continued safe and reliable operation of fire alarm, detection, mass notification, and emergency communication systems.

Work will be performed in accordance with applicable requirements, including NFPA 72, NFPA 101, UFC 3-600-01, Department of Defense/Navy installation directives, local Authority Having Jurisdiction (AHJ) requirements, and other applicable federal and local codes and standards. The Fire Alarm Technician serves as a subject matter expert for conventional, addressable, and mass notification fire alarm systems.

The position reports to the

Project Manager/Site Supervisor and works closely with the installation Fire Department, Facilities Engineering, and Government Quality Assurance Representative (QAR).

Duties and Responsibilities

  • Inspect, test, and maintain fire alarm control panels (FACP), initiating devices, notification appliances, and auxiliary control functions in accordance with NFPA 72 and applicable UFC standards.
  • Perform annual, semi-annual, and quarterly inspections of fire alarm systems as required by the Performance Work Statement (PWS).
  • Troubleshoot and repair fire alarm system malfunctions, including panel faults, open circuits, ground faults, device failures, and communication errors.
  • Replace or recalibrate smoke detectors, heat detectors, manual pull stations, horn/strobes, duct detectors, and other applicable devices as needed.
  • Test and verify the proper operation of mass notification systems (MNS), emergency voice/alarm communication systems (EVACS), and interfaces with building automation and suppression systems.
  • Maintain and update as-built drawings, device schedules, and panel programming documentation.
  • Ensure work complies with NFPA 72, NFPA 101, UFC 3-600-01, DoD/Navy installation directives, and applicable local AHJ requirements.
  • Document inspections, test results, deficiencies, and corrective actions in the Computerized Maintenance Management System (CMMS) and/or other government-required reporting formats.
  • Participate in quality control inspections, government QAR reviews, and safety inspections.
  • Maintain a clean and safe work environment and comply with applicable OSHA, installation safety, and environmental requirements.
  • Maintain required certifications and participate in continuing education and training as required.
  • Complete scheduled inspections within the timeframes established by the PWS and NFPA 72.
  • Complete and submit inspection reports within required contract timeframes.
  • Respond to emergency service calls within the response times established by the PWS.
  • Prepare deficiency reports and provide corrective-action recommendations within required timeframes.
  • Perform work in accordance with applicable NFPA, UFC, and AHJ standards and support satisfactory government QAR inspections.

Required Skills and Qualifications

  • High school diploma or GED required.
  • Associate's degree or technical/vocational training in electronics, electrical, or fire protection systems preferred.

Minimum of

3–5 years of experience inspecting, testing, and maintaining fire alarm systems in commercial, industrial, or government/military facilities.

Nicet

  • Fire Alarm Systems Level II certification required; Level III preferred.
  • Familiarity with military/DoD facility standards and UFC 3-600-01 strongly preferred.
  • Valid driver's license required, with the ability to operate government or company vehicles on the installation.
  • Must be able to obtain and maintain a
  • DoD/Navy Base Access credential
  • , including required background screening.
  • U.S. Citizenship required for base access.

Physical Requirements

  • Ability to lift and carry up to
  • 50 pounds.
  • Ability to work at heights using ladders, scaffolding, and aerial lifts.
  • Ability to work in confined spaces, attics, mechanical rooms, and crawl spaces.
  • Ability to work outdoors in Hawaii's tropical climate conditions.
  • Color vision sufficient to read wiring diagrams and identify color-coded conductors.
  • Ability to stand, walk, bend, and kneel for extended periods.

Work Schedule and Location

  • The standard work schedule is Monday through Friday, 7:00 AM to 3:30 PM, or as otherwise directed by the contract. On-call or emergency-response availability may be required, including participation in a rotating on-call schedule.
  • Work locations include Joint Base Pearl Harbor-Hickam and designated outlying areas, including Ford Island, Lualualei, West Loch, Barbers Point, Kunia, and other designated sites.
  • About Alakaʻi Services Group Inc. / Poʻe Hana Group, Inc.
  • Alaka‘i Services Group Inc. (ASGI), a subsidiary of the Alaka‘i Foundation Group Inc., is a Native Hawaiian Organization (NHO)-Owned Small Business serving the U.S. Department of Defense and other Federal Government Clients.
  • Headquartered in Honolulu, Hawaii, Poʻe Hana Group, Inc. (PGI) is a talent management, staffing, and administrative support services company. PGI specializes in providing HR and administrative services to the Alakaʻi family of NHO companies.
Read the original posting

From Asgi's careers page, posted on September 21, 2026, first listed on Rolev.ai on November 25, 2026. Rolev.ai is not the employer.

How Rolev.ai helps with this application

Rolev.ai is a job search and application tool for US job seekers. For this Fire Alarm Technician role at Asgi, it shows how your resume fits, tailors your resume to the posting, and prepares the application for you to review.

  • See how you fit

    Openings from employer career sites are ranked against your whole resume—and searchable inside Claude, ChatGPT, and Cursor via Rolev.ai MCP.

  • Tailor without inventing

    Every change to your resume is checked against your original. New experience goes in only with your yes—zero fabricated claims.

  • Draft the full kit

    Tailored and Full Match resumes, role-specific cover letters, and answers to employer screening questions are prepared in seconds.

  • 1-Click Extension Autofill

    The Chrome extension fills the employer's Greenhouse, Workday, Lever, or Ashby form in 1 click. You review it and press Submit.

Common questions

What is the salary for the Fire Alarm Technician role at Asgi?

The Fire Alarm Technician posting at Asgi states compensation of $85,000 – $95,000 per year. Final pay may depend on location, experience, and interview evaluation on Asgi's official career site.

Where is the Fire Alarm Technician job at Asgi located?

This Fire Alarm Technician position at Asgi is located in Honolulu, HI. Always check Asgi's application page for specific state eligibility or relocation policies.

How do I apply for the Fire Alarm Technician position at Asgi?

This listing links directly to Asgi's BambooHR application page. You can apply directly on Asgi's site, or use Rolev.ai to check your resume fit, generate a zero-hallucination tailored resume and cover letter for this posting, and autofill the BambooHR application form in 1 click with the Rolev.ai Chrome extension. You always review the form and press Submit yourself.