Skills & highlights for this role

  • Kentucky fire sprinkler certification
  • Kentucky fire alarm certification
  • Grinnell DCP-200 factory certification
  • driver's license
  • NFPA 72 fire alarm codes
  • NFPA 1031 plan review
  • fire sprinkler systems
  • life safety systems

Also useful

  • UPS systems
  • access control systems
Free · No account needed

How well does your resume fit this job?

Upload your resume to see your score for this Uofl role, what matches, what's missing, and your best other matches.

Scored on our server and not saved there. The file stays in this browser so you don't have to upload it again after you sign up.

Department

  • Location: Belknap Campus
  • Time Type: Full time
  • Worker Type: Regular
  • Job Req ID: R109134

Minimum Requirements

  • Associate's degree/Vocational Technical Training in Fire Science and/or Electronics and two (2) years of experience in maintenance of Fire and/or Life Safety Equipment.
  • Certified by the State of Kentucky to inspect and maintain Sprinkler Systems and/or Fire Alarm Systems.
  • Factory certification on Grinell DCP-200 and/or Grinell Mini-plex 1000 systems.
  • This certification can be used in place of the Fire Alarm or Sprinkler Systems Certification.
  • Valid driver's license and must be insurable through the University.
  • Must pass pre-employment physical.
  • Additional experience may be used on a one-to-one basis to offset the educational requirements.
  • Grade 5 (Hourly)

Position Description

The Fire & Life Safety Technician III position will install, repair, and inspect smoke and fire suppression systems and life safety systems. Inspect, test and repair fire alarm wiring, fire alarm panels, fire alarm related devices and test fire alarm systems, life safety equipment and peripheral equipment. Identifies hazard defects and the need for adjustment or repair. Follow up on corrective actions.

Understand the National, State and Local Fire Safety Codes and law that pertain to the University Buildings. Troubleshoot alarms and answer calls regarding life safety devices and perform general building maintenance and preventative maintenance as assigned. Maintain all UPS Systems, security panels and card readers for all University facilities.

This position responds to emergencies and is designated as critical personnel. The employee is required to participate in standby and on-call rotations and must be physically present in the workplace as needed. The employee must report to or remain at work during University emergencies or closures and maintain a valid driver’s license that meets the University’s insurability requirements.

Essential Duties and Responsibilities

  • Responsible for inspections, testing, emergency response and maintaining facility life safety and security systems.
  • Assist with installation or upgrades on fire alarms in University campus buildings.
  • Perform inspections to ensure alarms are installed according to codes, standards and properly functioning.
  • Working knowledge of current building, fire and life safety codes as related to fire alarms.
  • Perform plan review of new and existing fire and life systems per NFPA 1031.
  • Test and repair alarm systems already installed.
  • Experience with and ability to diagnose fire alarm system issues and to maintain, adjust repair, and replace a variety of fire alarms and related components.
  • Performs periodic maintenance on fire alarm systems equipment in accordance with the PM Program, NFPA and manufacturer's guidelines.
  • Diagnoses, repairs, and performs scheduled Preventative Maintenance on existing fire alarm, detection, notification, and reporting systems.
  • Ensures compliance with the applicable IBC, IFC and NFPA codes, UFC Code and satisfaction of the Authority Having Jurisdiction (AHJ).
  • Properly document deficiencies/impairments noted during inspections or service work and follow required process of reporting deficiencies while on-site.
  • Respond to campus fire & life safety emergencies of: Fire and sprinkler activations, security alarms, elevator alarms, process alarms, power outages, and general emergencies affecting campus community.
  • Perform life safety detail during sporting and special dignitary events.
  • Assist with or perform installation, repair, and maintenance of wet, dry, pre-action, and deluge fire sprinkler systems, standpipes, backflow preventers, fire hydrants, underground and fire pumps.
  • Assist with or perform fire sprinkler, fire pump and other water-based equipment inspections and testing.
  • Adhere to local, corporate, and OSHA safety policies and procedures.

Preferred Qualifications

  • Knowledge of NFPA standards is a plus (including 70 and 72).
  • Requisite Knowledge of NFPA standards of and including: NFPA 1 National Fire Code, 10 Fire Extinguishers, 13 Fire Sprinkler Installations, 17a/96 Chemical Rangehood Systems, 20 Fire Pumps, 25 Inspecting testing fire sprinkler, 70 & 70e Electrical codes, 72 Fire Alarm & Signaling code, 90/90a HVAC & Duct smoke code, 92 Atria Smoke Control Systems, 101 Life Safety code, 291 Fire hydrants & fire mains, 1031 Fire inspector & Plan reviewer and 2001 Clean agent systems).
  • Be able to work in various environments of: Office, Residential (Dorm), Commercial, Industrial, Institutional, Level I, II & III labs and adhere to procedures and protocols associated with each environment.
  • Working knowledge of Sprinkler systems. (Sprinkler Inspectors License not required).
  • Experience in maintaining and troubleshooting electrical and low voltage systems, systems, such as security systems, access control, and fire alarm systems.

Compensation will be commensurate to candidate experience.

Read the original posting

From Uofl's careers page, first listed on Rolev.ai on October 20, 2026. Rolev.ai is not the employer.

How Rolev.ai helps with this application

Rolev.ai is a job search and application tool for US job seekers. For this Fire & Life Safety Technician III role at Uofl, it shows how your resume fits, tailors your resume to the posting, and prepares the application for you to review.

  • See how you fit

    Openings from employer career sites are ranked against your whole resume—and searchable inside Claude, ChatGPT, and Cursor via Rolev.ai MCP.

  • Tailor without inventing

    Every change to your resume is checked against your original. New experience goes in only with your yes—zero fabricated claims.

  • Draft the full kit

    Tailored and Full Match resumes, role-specific cover letters, and answers to employer screening questions are prepared in seconds.

  • 1-Click Extension Autofill

    The Chrome extension fills the employer's Greenhouse, Workday, Lever, or Ashby form in 1 click. You review it and press Submit.

Common questions

Where is the Fire & Life Safety Technician III job at Uofl located?

This Fire & Life Safety Technician III position at Uofl is located in Louisville, KY (On-site). Always check Uofl's application page for specific state eligibility or relocation policies.

What qualifications are required for Fire & Life Safety Technician III at Uofl?

For the Fire & Life Safety Technician III role, Uofl highlights 2+ years of relevant experience; a associate degree; experience with NFPA 72 fire alarm codes, NFPA 1031 plan review, fire sprinkler systems, life safety systems. Rolev.ai can score your existing resume against these requirements and show any skill gaps before you apply.

How do I apply for the Fire & Life Safety Technician III position at Uofl?

This listing links directly to Uofl's Workday application page. You can apply directly on Uofl's site, or use Rolev.ai to check your resume fit, generate a zero-hallucination tailored resume and cover letter for this posting, and autofill the Workday application form in 1 click with the Rolev.ai Chrome extension. You always review the form and press Submit yourself.